Analysis of Capacitor Unbalance Protection activation due to AC filter tripping incident at ±660kV HVDC Lahore converter station

Muhammad Imran, Abdullah Naveed, Habib Ullah, Mohammad Ahsan Shehzad, Zhang Jianmeng.


Abstract
This study examines an AC filter tripping incident that occurred at Lahore Converter station of ±660kV high voltage direct current (HVDC) Pak Matiari-Lahore transmission project which seriously affected the stable operation of the converter station. The fault current exceeded the trip threshold and lasted for more than 20 milliseconds, causing the activation of capacitor unbalance protection. The short circuit discharge phenomenon occurring between the layers of the capacitors is responsible for tripping the filter leading to the activation of capacitor unbalance protection. The incident emphasizes how important protection methods are to maintaining system stability in unusual circumstances. The fault mechanism is thoroughly examined, including its underlying causes and modes of transmission. In order to prevent the expensive equipment from damage, the study highlights the importance of precise protective settings. To reduce future dangers, suggestions are made for better operation and maintenance procedures and cutting-edge monitoring systems. By taking these measures, the AC filter's robustness and dependability will be improved, especially during difficult grid circumstances like periods of high demand.

Key words: Capacitor unbalance protection, AC filter trip, HVDC converter station


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Muhammad Imran
Articles by Abdullah Naveed
Articles by Habib Ullah
Articles by Mohammad Ahsan Shehzad
Articles by Zhang Jianmeng
on Google
on Google Scholar


How to Cite this Article
Pubmed Style

Imran M, Naveed A, Ullah H, Shehzad MA, Jianmeng Z. Analysis of Capacitor Unbalance Protection activation due to AC filter tripping incident at ±660kV HVDC Lahore converter station. J Eng Res Rev. Online First: 31 Mar, 2025. doi:10.5455/JERR.20250102040226


Web Style

Imran M, Naveed A, Ullah H, Shehzad MA, Jianmeng Z. Analysis of Capacitor Unbalance Protection activation due to AC filter tripping incident at ±660kV HVDC Lahore converter station. https://www.wisdomgale.com/jerr/?mno=235799 [Access: April 10, 2025]. doi:10.5455/JERR.20250102040226


AMA (American Medical Association) Style

Imran M, Naveed A, Ullah H, Shehzad MA, Jianmeng Z. Analysis of Capacitor Unbalance Protection activation due to AC filter tripping incident at ±660kV HVDC Lahore converter station. J Eng Res Rev. Online First: 31 Mar, 2025. doi:10.5455/JERR.20250102040226



Vancouver/ICMJE Style

Imran M, Naveed A, Ullah H, Shehzad MA, Jianmeng Z. Analysis of Capacitor Unbalance Protection activation due to AC filter tripping incident at ±660kV HVDC Lahore converter station. J Eng Res Rev, [cited April 10, 2025]; Online First: 31 Mar, 2025. doi:10.5455/JERR.20250102040226



Harvard Style

Imran, M., Naveed, . A., Ullah, . H., Shehzad, . M. A. & Jianmeng, . Z. (2025) Analysis of Capacitor Unbalance Protection activation due to AC filter tripping incident at ±660kV HVDC Lahore converter station. J Eng Res Rev, Online First: 31 Mar, 2025. doi:10.5455/JERR.20250102040226



Turabian Style

Imran, Muhammad, Abdullah Naveed, Habib Ullah, Mohammad Ahsan Shehzad, and Zhang Jianmeng. 2025. Analysis of Capacitor Unbalance Protection activation due to AC filter tripping incident at ±660kV HVDC Lahore converter station. Journal of Engineering Research and Reviews, Online First: 31 Mar, 2025. doi:10.5455/JERR.20250102040226



Chicago Style

Imran, Muhammad, Abdullah Naveed, Habib Ullah, Mohammad Ahsan Shehzad, and Zhang Jianmeng. "Analysis of Capacitor Unbalance Protection activation due to AC filter tripping incident at ±660kV HVDC Lahore converter station." Journal of Engineering Research and Reviews Online First: 31 Mar, 2025. doi:10.5455/JERR.20250102040226



MLA (The Modern Language Association) Style

Imran, Muhammad, Abdullah Naveed, Habib Ullah, Mohammad Ahsan Shehzad, and Zhang Jianmeng. "Analysis of Capacitor Unbalance Protection activation due to AC filter tripping incident at ±660kV HVDC Lahore converter station." Journal of Engineering Research and Reviews Online First: 31 Mar, 2025. Web. 10 Apr 2025 doi:10.5455/JERR.20250102040226



APA (American Psychological Association) Style

Imran, M., Naveed, . A., Ullah, . H., Shehzad, . M. A. & Jianmeng, . Z. (2025) Analysis of Capacitor Unbalance Protection activation due to AC filter tripping incident at ±660kV HVDC Lahore converter station. Journal of Engineering Research and Reviews, Online First: 31 Mar, 2025. doi:10.5455/JERR.20250102040226